Comment le testeur complet du corps humain teste-t-il séparément le bracelet et les chaussures anti-statiques ?



The human body comprehensive tester can effectively monitor the static electricity on the human body, and can effectively remove the static electricity on the human body. The human body comprehensive tester mainly tests the comprehensive resistance value of the human body. This instrument can detect and alarm the resistance (greater than 109 1010Ω) of human body static electricity that is easy to accumulate dangerous, and when the comprehensive resistance of the human body is too small (less than 104Ω), If the staff accidentally touches the power supply (220V or 380V), it will cause an electric shock injury accident, and also alarm to prevent personnel electric shock accident.
Voici la méthode d'utilisation spécifique du testeur complet du corps humain :
When testing the wrist strap, first put the wrist strap on the wrist, insert the banana plug of the wrist strap into the yellow socket on the front of the instrument, turn the test selector switch to the "wrist strap" side, and press the test button. If the passage resistance of the wrist strap meets the standard requirements, the "pass" indicator in the middle will light up. If it does not meet the standard requirements, the corresponding indicator lights on the left and right will display "low" or "high", and the sound will alarm at the same time.
To test anti-static shoes, step on the pedals with both feet, open the test selector switch to the "footplate" side, and press the test button. If the path resistance of the shoe meets the standard requirements, the "pass" indicator light in the middle will light up. If it does not meet the standard requirements, the corresponding indicator lights on the left and right will display "low" or "high", and the sound will alarm at the same time.
L'électricité statique du corps humain est le facteur principal et le plus fréquent qui provoque l'explosion inattendue d'explosifs et d'explosifs électriques, qui endommage les appareils électroniques et provoque des dysfonctionnements de l'équipement. Les exigences sont principalement basées sur la protection électrostatique du corps humain. Dans le problème anti-statique du corps humain, mesurer la résistance globale du corps humain est l'une des méthodes les plus importantes et les plus efficaces.